I-KCO-Fiver-MTP-MPO-QSFP-Banner-page-1

I-Single Mode G652D G657A1 GYTS 12 Core Pipeline Outdoor Fiber Optic Cable

Incazelo emfushane:

+ Sebenzisa ngaphandle njengepayipi, ngaphansi komhlaba, ipayipi noma ukungcwaba okuqondile

+ Inani le-fiber: imicu emi-2, imicu emi-4, imicu emi-6, imicu emi-8, imicu eyi-12, imicu engama-24

+ Uhlobo lwefayibha:

I-SM: G652D, SM G657A1, SM G657A2, G655

MM: OM1, OM2, OM3, OM4, OM5

+ Ikhebula elingaphandle kwesikhwama: PE, elimnyama

+ Ububanzi bekhebula: 7.0mm (6.5mm, 8.0mm uma uthanda)

+ Ukuphrinta nokulebula ikhebula: yamukela.


  • Intengo ye-FOB:US $0.5 - 9,999 / Isiqephu
  • Ubuningi be-Order encane:Izingcezu/Izingcezu eziyi-100
  • Amandla Okunikezela:Izingcezu/Izingcezu eziyi-10000 ngenyanga
  • Imininingwane Yomkhiqizo

    Amathegi Omkhiqizo

    Idatha Yobuchwepheshe Yekhebula le-GYTS

    Into

    Amapharamitha

    Ipayipi elikhululekile

    Izinto

    I-PBT

    Umbala

    I-spectrum yombala ogcwele

    Isigcwalisi

    Izinto

    PE

    Umbala

    Okumnyama

    I-CSM

    Izinto

    Intambo yensimbi ye-phosphate

    Ihlomile

    Izinto

    Umugqa we-aluminium ombozwe ngepulasitiki

    Ijakethi yangaphandle

    Izinto

    I-MDPE

    Umbala

    Okumnyama

    Irediyasi encane yokugoba

    Okungaguquki

    Ububanzi bekhebula obuphindwe kayishumi

    I-Dynamic

    Ububanzi bekhebula obuphindwe ka-20

    Ukugoba okuphindaphindiwe

    Umthwalo150N;inani lemijikelezo: 30 Akukho ukuncishiswa okusobala kokungezwa, akukho ukuphuka kwefayibha futhi akukho monakalo wekhebula.

    Ukusebenza kokudonsa

    Isikhathi esifushane

    1500N

    Ukuchoboza

    Isikhathi esifushane

    1000N/100mm

    I-Torsion

    Umthwalo150N; inani lemijikelezo: 10; i-angle yokujika:±180° Akukho ukuncishiswa okusobala kokungezwa, akukho ukuphuka kwefayibha futhi akukho monakalo wekhebula.

    Umthelela

    Amandla omthelela450g×1m; irediyasi yekhanda lesando: 12.5mm; inani lomthelela: 5 Akukho ukuncishiswa okusobala kokungezwa, akukho ukuphuka kwefayibha futhi akukho monakalo wekhebula.

    Isici sefayibha:

    Isitayela sefayibha Iyunithi SM

    G652D

    SM

    G657A

    MM

    50/125

    MM

    62.5/125

    MM

    OM3-300

    MM

    OM4-550

    Isimo nm 1310/1550 1310/625 850/1300 850/1300 850/1300 850/1300
    Ukuncipha i-dB/km ≤0.34/0.22 ≤.035/0.21 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0 ≤3.5/2.2
    Ukuhlakazeka 1550nm I-Ps/(nm*km) ≤18 ≤18 ---- ----

    ----

    ----

      1625nm I-Ps/(nm*km) ≤22 ≤22 ---- ----

    ----

    ----

    Ububanzi bomkhawulo 850nm I-MHZ.KM ----   ≥400 ≥160    
      1300nm I-MHZ.KM ----   ≥800 ≥500
    Ububanzi be-wavelength obungaphelele nm ≥1302

    ≤1322

    ≥1302

    ≤1322

    ---- ---- ≥ 1295,

    ≤1320

    ≥ 1295,

    ≤1340

    Umthambeka wokuhlakazeka ongenalutho nm ≤0.091 ≤0.090 ---- ---- ---- ----
    I-PMD Maximum Individual Fiber ≤0.2 ≤0.2 ---- ---- ≤0.11  
    Inani Lesixhumanisi Sokuklama se-PMD Ama-Ps(nm2*km) ≤0.08 ≤0.1 ---- ---- ---- ----
    ubude be-wavelength obunqunyiwe befayibha λc nm ≥1180

    ≤1330

    ≥1180

    ≤1330

    ---- ---- ---- ----
    Ukunqanyulwa kwekhebula

    ubude be-wavelength λcc

    nm ≤1260 ≤1260 ---- ---- ---- ----
    I-MFD 1310nm um 9.2±0.4 9.0±0.4 ---- ---- ---- ----
      1550nm um 10.4±0.8 10.1±0.5 ---- ---- ---- ----
    Izinombolo

    Imbobo (NA)

    ---- ---- 0.200± 0.015 0.275±

    0.015

    0.200±

    0.015

    0.200±

    0.015

    Isinyathelo (isilinganiso sezinhlangothi ezimbili

    isilinganiso)

    dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Ukungalingani ngobude befayibha kanye nephuzu dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Umehluko obuyela emuva

    i-coefficient

    i-dB/km ≤0.03 ≤0.03 ≤0.08 ≤0.10 ≤0.08 ≤0.08
    Ukufana kokunciphisa i-dB/km ≤0.01 ≤0.01  
    Ububanzi be-core um 9 9 50±1.0 62.5±2.5 50±1.0 50±1.0
    Ububanzi bokumboza um 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1
    Ukungaguquguquki kwe-cladding % ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0
    Ububanzi bokumboza um 242±7 242±7 242±7 242±7 242±7 242±7
    Ukugqoka/utshani

    iphutha eligxile ngaphakathi

    um ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0
    Ukugqoka okungajikelezi % ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0
    Iphutha lokugxilisa ingqondo eliyinhloko/elimboziwe um ≤0.6 ≤0.6 ≤1.5 ≤1.5 ≤1.5 ≤1.5
    I-curl (irediyasi) um ≤4 ≤4 ---- ---- ---- ----

    Umbala wefayibha:

    1 2 3 4 5 6
    Okuluhlaza okwesibhakabhaka iwolintshi Okuluhlaza okotshani Insundu Okumpunga Okumhlophe
    7 8 9 10 11 12
    Okubomvu Okumnyama Ophuzi I-Violet Opinki Amanzi
    Ikhodi Yemibala Yekhebula Le-Fibre-Optic

    Incazelo Yekhebula le-GYTS

    + I-GYTS (ilungu lokuqinisa insimbi, ikhebula le-fiber optical fiber elingaphandle eliboshwe ngensimbi neligcwele, eliboshwe nge-polyethylene ukuze kuxhunyaniswe ngalo).

    + Isakhiwo sekhebula le-optical siwukufaka i-fiber ye-optical yemodi eyodwa noma yemodi eminingi ekugcwaliseni kwangaphakathi okwenziwe ngepulasitiki ephezulu. Inhlanganisela engangeni manzi eshubhu elikhululekile.

    + Isikhungo se-cable core singumgogodla oqiniswe ngensimbi. Kwezinye izintambo ze-fiber optic, i-metal steel core nayo ikhishwa ngesendlalelo se-polyethylene (PE).

    + Ithubhu elikhululekile (nentambo yokugcwalisa) lisontiwe lizungeze umongo wokuqinisa ophakathi ukuze kwakhiwe umongo wekhebula ohlangene noyindilinga, kanti izikhala ezikumongo wekhebula zigcwele izinto ezivimba amanzi.

    + Itheyiphu ehlanganisiwe yensimbi-yepulasitiki igoqwa ngobude bese ikhishwa ngesikhwama se-polyethylene.

    Ukwakhiwa Kwekhebula le-GYTS:

    Ikhebula le-KCO GYTS

    Izici zekhebula le-GYTS:

    + Ukusebenza kahle kwemishini kanye nokushisa

    + Ishubhu elikhululekile elinamandla aphezulu elingamelana ne-hydrolysis

    + Inhlanganisela ekhethekile yokugcwalisa amashubhu iqinisekisa ukuvikelwa okubalulekile kwefayibha

    + Isakhiwo esincane esakhelwe ngokukhethekile sihle ekuvimbeleni amashubhu axegayo ukuthi anganciphi

    + Isikhwama se-PE sivikela ikhebula emisebeni ye-ultraviolet

    + Kuthathwa izinyathelo ezilandelayo ukuqinisekisa ukuthi ikhebula alingeni manzi:

    + Ucingo lwensimbi olusetshenziswa njengelungu eliphakathi lamandla

    + Ingxube yokugcwalisa ishubhu ekhululekile

    + 100% ukugcwaliswa kwe-core yekhebula

    + 100% ihlolwe ngaphambi kokuthunyelwa.

    + Ubude be-reel yekhebula: 1km, 2km, 3km, 5km

    Isicelo sekhebula le-GYTA:

    + Yamukelwe ekusakazweni kwangaphandle.

    + Kufanelekela ukufakwa kwamapayipi, ukungcwaba ngqo, indlela engaphansi komhlabathi.

    + Ukuxhumana kwenethiwekhi yebanga elide nendawo.

    Ukupakisha:

    I-KCO FIber - Ukupakisha Ikhebula Langaphandle

  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi