I-KCO-Fiver-MTP-MPO-QSFP-Banner-page-1

I-AOC DAC

6377837608805668685213055
Ikhebula le-Optical elisebenzayo le-SFP+ elingu-10Gb/s

Ikhebula le-Optical elisebenzayo le-SFP+ elingu-10Gb/s

- Amakhebula e-KCO-SFP-10G-AOC-xM ahambisana ne-SFP+ Active Optical ahlanganisa i-fiber ngqo anezixhumi ze-SFP+ futhi asebenza nge-Multi-Mode Fiber (MMF).

- Le KCO-SFP-10G-AOC-xM AOC iyahambisana nezindinganiso ze-SFF-8431 MSA.

- Ihlinzeka ngesisombululo esingabizi kakhulu uma kuqhathaniswa nokusebenzisa ama-transceivers e-optical ahlukene kanye nezintambo ze-optical patch futhi ifaneleka ekuxhumaneni kwe-10Gbps ngaphakathi kwama-racks nakuzo zonke izingcezu eziseduze.

- Ama-optics agcwele ngaphakathi kwekhebula, okuthi—ngaphandle kwezixhumi ze-LC optical zokuhlanza, ukuklwebha, noma ukuphuka—kukhuphule kakhulu ukuthembeka futhi kunciphisa izindleko zokulungisa.

- Ama-AOC avame ukusetshenziswa kakhulu ekudaleni izixhumanisi ezimfushane ze-switch-to-switch noma i-switch-to-GPU ezingamamitha ayi-1-30.

Ikhebula le-Optical elisebenzayo elingu-40Gb/s QSFP+ UKUYA KU-QSFP+ elingu-Active Optical

Ikhebula le-Optical elisebenzayo elingu-40Gb/s QSFP+ UKUYA KU-QSFP+ elingu-Active Optical

-Sekela uhlelo lokusebenza lwe-40GBASE-SR4/QDR

- Ihambisana ne-QSFP+ Electrical MSA SFF-8436

- Isilinganiso esiningi esifinyelela ku-10.3125Gbps

- Ukunikezwa kwamandla okukodwa okungu-+3.3V

- Ukusetshenziswa kwamandla okuphansi

- Izinga lokushisa lekesi lokusebenza: Kwezentengiselwano: 0°C kuya ku-+70°C

- Ukuthobela i-RoHS

Ikhebula le-Optical elisebenzayo le-SFP28 elingu-100Gb/s

Ikhebula le-Optical elisebenzayo le-SFP28 elingu-100Gb/s

- Sekela uhlelo lokusebenza lwe-100GBASE-SR4/EDR

- Iyahambisana ne-QSFP28 Electrical MSA SFF-8636

- Isilinganiso esiningi esifinyelela ku-25.78125Gbps

- Ukunikezwa kwamandla okukodwa okungu-+3.3V

- Ukusetshenziswa kwamandla okuphansi

- Izinga lokushisa lekesi lokusebenza Kwezentengiselwano: 0°C kuya ku-+70°C

- Ukuthobela i-RoHS

Ikhebula le-MMF elisebenzayo le-AOC Active Optical eliyi-400Gb/s QSFP-DD kuya ku-2x200G QSFP56 AOC

Ikhebula le-MMF elisebenzayo le-AOC Active Optical eliyi-400Gb/s QSFP-DD kuya ku-2x200G QSFP56 AOC

Amakhebula e-optical asebenzayo e-KCO-QDD-400-AOC-xM aklanyelwe ukusetshenziswa kuma-link angu-400 Gigabit Ethernet phezu kwama-fiber e-OM4 multimode, futhi aqukethe ama-transceiver optic fibers ayisishiyagalombili (MMF) optic fibers ngokuphela ngakunye, ngalinye lisebenza ngamanani edatha afinyelela ku-53Gb/s.

Le ntambo esebenzayo ye-optical ihambisana ne-IEEE 802.3cd, OIF-CEI-04.0, QSFP-DD MSA, kanye ne-QSFP-DD-CMIS-rev4p0.

Izintambo ze-AOC ezincane nezilula zenza kube lula ukuphathwa kwezintambo, okuvumela ukuhamba komoya ohlelweni okuphumelelayo, okubaluleke kakhulu kuma-rack anabantu abaningi.

Isetshenziswa kakhulu kuma-cloud nama-supercomputer ngenxa yezindleko zayo eziphansi, isiphakamiso sayo senani eliphezulu, kanye nokwethenjelwa okwandisiwe.

Ikhebula le-Optical elisebenzayo le-200G QSFP-DD OM3

Ikhebula le-Optical elisebenzayo le-200G QSFP-DD OM3

Ikhebula le-optical elisebenzayo le-KCO-200G-QSFP-DD-xM lenzelwe ukusetshenziswa kuma-link angu-200 Gigabit Ethernet ngaphezu kwe-OM3 multimode fiber.

Le ntambo esebenzayo ye-optical ye-KCO-200G-QSFP-DD-xM ihambisana ne-QSFP-DD MSA V5.0 kanye ne-CMIS V4.0.

Ihlinzeka ngokuxhumeka kwechweba le-200G QSFP-DD kwamanye amachweba e-QSFP-DD futhi ifaneleka ukuxhumana okusheshayo nokulula ngaphakathi kwama-rack nakweminye i-rack eseduze.

I-Cisco QSFP-4 x 10G-AOC1M Ihambisana ne-40G QSFP+ kuya ku-4 x 10G SFP+ Ikhebula Lokuqhekeka Elisebenzayo Le-Optical

I-Cisco QSFP-4 x 10G-AOC1M Ihambisana ne-40G QSFP+ kuya ku-4 x 10G SFP+ Ikhebula Lokuqhekeka Elisebenzayo Le-Optical

- Ikhebula le-KCO-40QSFP-4SFP10-AOC-xM le-Cisco QSFP-4X10G-AOC1M elihambisana ne-40G QSFP+ kuya ku-4 SFP+ Breakout Active Optical lisebenza nge-Multi-Mode Fiber (MMF).

- Le khebula eliphumayo liyahambisana nezindinganiso ze-SFF-8436, SFF-8431 kanye ne-SFP+ kanye ne-QSFP MSA.

- Ihlinzeka ngokuxhumeka kwechweba le-40G QSFP+ kolunye uhlangothi kanye namachweba amane e-10G SFP+ kolunye uhlangothi futhi ifaneleka ukuxhumana okusheshayo nokulula ngaphakathi kwama-rack nakweminye i-rack eseduze.

I-Cisco Compatible 1G SFP Passive Direct Namathisela i-Copper Twinax Cable SFP ku-SFP 30AWG

I-Cisco Compatible 1G SFP Passive Direct Namathisela i-Copper Twinax Cable SFP ku-SFP 30AWG

- Ikhebula le-KCO-1G-DAC-xM 1G SFP Passive Direct Attach Copper Twinax Cable lenzelwe ukusetshenziswa ku-1GBASE Ethernet.

- Le khebula le-KCO-1G-DAC-xM DAC lihambisana ne-SFF-8472, SFF-8024, kanye ne-SFP+ MSA.

- Ngalezi zici, le ntambo ye-twinax yethusi elula ukuyifaka, esheshayo, nengabizi kakhulu ifaneleka ukuxhumana ibanga elifushane ngaphakathi kwe-rack noma phakathi kwama-rack aseduze ezikhungweni zedatha.

Ikhebula le-Twinax le-SFP-H10GB-CU1M elihambisana ne-10G SFP+ Passive Direct Attach Copper

Ikhebula le-Twinax le-SFP-H10GB-CU1M elihambisana ne-10G SFP+ Passive Direct Attach Copper

- Ukusetshenziswa Kwamandla Okuphezulu 0.1W

- Amaswishi Ahlolwe Ukusebenza Okuhle, Ikhwalithi, Nokuthembeka

- Irediyasi Egobile Encane engu-23mm Yomzila Oguquguqukayo

- Isixazululo Esilula Sokupesha kanye Nezixhumanisi Ezifushane Ezingabizi Kakhulu

I-Cisco SFP-H25G-CU1M Iyahambisana ne-25G SFP28 Passive Direct Attach Copper Twinax Cable

I-Cisco SFP-H25G-CU1M Iyahambisana ne-25G SFP28 Passive Direct Attach Copper Twinax Cable

- Isekela kufika ku-25.78 Gbps ukuze kudluliselwe idatha ngendlela ephumelelayo

- Umqhubi wethusi ofakwe isiliva ukuze kuthuthukiswe ikhwalithi yesiginali

- Ihambisana nezindinganiso eziningi kufaka phakathi i-IEEE P802.3by kanye ne-SFF-8402

- Yakhelwe ngejakethi ye-PVC eqinile kanye nerediyasi yokugoba engu-30 mm ukuze kube nokuguquguquka okuthuthukisiwe

- Isilinganiso Sephutha Eliphansi Le-Bit (BER) 1E-15 siqinisekisa ukuxhumana okuthembekile

I-Cisco QSFP-H40G-CU1M Iyahambisana ne-40G QSFP+ Passive Direct Namathisela Ikhebula Lethusi

I-Cisco QSFP-H40G-CU1M Iyahambisana ne-40G QSFP+ Passive Direct Namathisela Ikhebula Lethusi

- Ihambisana ngokugcwele ne-IEEE802.3ba kanye ne-Infiniband QDR specifications

- I-bandwidth iyonke engu-40 Gb/s

- Iziteshi ze-duplex ezizimele ezine ezisebenza ku-10Gbps, futhi zisekela amazinga edatha angu-2.5Gbps, 5Gbps

- Ukunikezwa kwamandla okukodwa okungu-3.3V.

- Ukusetshenziswa kwamandla okuphansi <1.5W

- Usayizi wekhebula we-AWG ongu-30 kuya ku-24 uyatholakala

- Ukuthobela i-RoHS, i-QSFP MSA

- I-InfiniBand Trade Association ehambisanayo (IBTA), i-40Gigabit Ethernet (40G BASE – CR4)

- Isicelo Sokuxhumana Kwesikhungo Sedatha, Izinhlelo Zokugcina Ezinenethiwekhi, Amaswishi, kanye Nama-Routers

I-Cisco QSFP-100G-CU1M Iyahambisana ne-100G QSFP28 Passive Direct Namathisela Ikhebula Le-Twinax Lethusi

I-Cisco QSFP-100G-CU1M Iyahambisana ne-100G QSFP28 Passive Direct Namathisela Ikhebula Le-Twinax Lethusi

- I-QSFP28 ivumelana ne-Small Form Factor SFF-8665
- I-Transceiver Yekhebula Lethusi Eligcwele I-Duplex Eneziteshi Ezi-4
- Ukusekelwa kwamazinga edatha e-multi-gigabit: 25.78Gb/s (ngesiteshi ngasinye)
- Isilinganiso sedatha esiphezulu: 100Gb/s (4 x 25.78Gb/s)
- Ubude besixhumanisi sethusi bufika ku-3m (umkhawulo ongenzi lutho)
- Isixhumi se-QSFP esingu-38-PIN esinobuningi obuphezulu
- Ukunikezwa Kwamandla: +3.3V
- Ukusetshenziswa kwamandla okuphansi: 0.02 W (uhlobo)
- Izinga Lokushisa: 0 ~ 70 °C
- Ihambisana ne-ROHS

I-Cisco QSFP-4SFP25G-CU1M Iyahambisana ne-100G QSFP28 kuya ku-4 x 25G SFP28 Passive Direct Attach Copper Breakout Cable

I-Cisco QSFP-4SFP25G-CU1M Iyahambisana ne-100G QSFP28 kuya ku-4 x 25G SFP28 Passive Direct Attach Copper Breakout Cable

- Iyahambisana ne-SFF-8665

- Kufika ku-28.3125Gbps ngesilinganiso sedatha ngesiteshi ngasinye

- Ukudluliselwa kufika ku-5m

- Ukunikezwa kwamandla okukodwa okungu-3.3V

- Ukuthobela i-RoHS

Iyini i-fiber optic DAC kanye ne-fiber optic AOC?

+ Ikhebula Lethusi Elinamathiselwe Ngokuqondile (i-DAC) ngokuvamile lihunyushwa njengekhebula lokuxhuma ngqo noma ikhebula lethusi elixhumeke ngqo, ukuhlanganiswa kwekhebula elinezixhumi eziqinile kuzo zombili izinhlangothi, futhi ikhanda lemojuli nekhebula lethusi akukwazi ukuhlukaniswa. I-DAC ihlukaniswe ngekhebula lethusi elingasebenzi kanye nekhebula lethusi elisebenzayo. I-DAC idlulisela zonke izimpawu zikagesi, futhi ayihileli ukuguqulwa kukagesi kube ukukhanya noma ukukhanya kube ugesi.

+ I-DAC inezindleko eziphansi kanye nokusetshenziswa kwamandla okuphansi, kodwa ibanga lokudlulisela lifushane. Igxile kakhulu ezimweni zokusetshenziswa zemitha eli-1 kuya kumamitha ama-5. Isakhiwo somkhiqizo silula, izingxenye zimbalwa, futhi ukuthembeka kuphezulu. Ifanele izinhlelo zokusebenza zebanga elifushane ezidinga izindleko eziphansi kanye nokusetshenziswa kwamandla okuphansi.

+ Ikhebula Elisebenzayo Elibonakalayo (AOC), elihunyushwe ngokuthi ikhebula elisebenzayo elibonakalayo. Kunamamojula amabili kuzo zombili izinhlangothi ze-AOC, kanye nocezu lwefayibha phakathi. Kukhona ama-transmitter e-optical kanye nama-receiver e-optical kumabhodi wesekethe kumamojula kuzo zombili izinhlangothi ze-AOC. Imisebenzi yawo ukuguqula amasignali kagesi abe amasignali e-optical ekugcineni kokudlulisa, ukuwadlulisela ku-fiber e-optical, bese eguqula amasignali e-optical abe amasignali kagesi ekugcineni kokwamukela. Ngenxa yokuthi isebenzisa ukudluliswa kwesignali ye-optical, ibanga lokudlulisa lide kunele-DAC, kodwa ngenxa yokuguqulwa kwe-photoelectric okuhilelekile, ubuchwepheshe bokuklama nokucubungula buyinkimbinkimbi kakhulu, futhi izindleko kanye nokusetshenziswa kwamandla nakho kuphakeme.

+ I-AOC inebanga elide lokudlulisa, futhi ubude obuvamile busukela kumitha eli-1 kuya kumamitha angama-30. Kodwa-ke, imikhiqizo ye-AOC enobude obungaphezu kwamamitha angama-300 nayo ingenziwa ngokwezifiso, kodwa izindleko ziphezulu futhi ukusetshenziswa kwamandla kuphezulu, okulungele izimo ezidinga izintambo ezilula noma ibanga elide lokudlulisa.

Ukugeleza Kokukhiqiza kwe-SFP / QSFP/ DAC/ AOC

Inqubo