Ikhasi lesibhengezo

I-KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

Incazelo emfushane:

I-KCO SFP+ 10G ER iyindinganiso ye-10 Gigabit Ethernet phezu kwezintambo ze-fiber optic, eziklanyelwe ngokukhethekile ukudluliswa kwebanga elide.

Ivumela ukudluliswa kwedatha kufika ku-40 km ngefayibha yemodi eyodwa (SMF) kubude begagasi obungu-1550nm.

I-KCO SFP+ 10G ER fiber optic modules, evame ukusetshenziswa njengama-transceivers e-SFP+, asetshenziswa ezinhlelweni ezihlukahlukene lapho kudingeka khona ukufinyelela okunwetshiwe, njengokuxhuma izakhiwo ku-campus enkulu noma ngaphakathi kwenethiwekhi yendawo yedolobha elikhulu.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

I-KCO-SFP+-10G-ER

+ I-KCO SFP+ 10G ER iyindinganiso ye-10 Gigabit Ethernet phezu kwezintambo ze-fiber optic, eziklanyelwe ngokukhethekile ukudluliswa kwebanga elide.

+ Ivumela ukudluliswa kwedatha kufikela ku-40 km ngefayibha yemodi eyodwa (SMF) kubude obuyi-1550nm.

+ I-KCO SFP+ 10G ER amamojula we-fiber optic, avame ukusetshenziswa njengama-transceivers e-SFP+, asetshenziswa ezinhlelweni ezihlukahlukene lapho kudingeka khona ukufinyelela okunwetshiwe, njengokuxhuma izakhiwo ku-campus enkulu noma ngaphakathi kwenethiwekhi yendawo yedolobha elikhulu.

Izici Zomkhiqizo

+ Kufika ku-11.1Gbps Data Links

+ Kufika ku-40km ukudluliselwa ku-SMF

+ I-EML Transmitter kanye ne-PIN receiver

+ Insimbi ebiyelwe, ye-EMI ephansi

+ I-interface ye-2-wire enokuqapha okuhlanganisiwe kwe-Digital Diagnostic

+ I-Hot-pluggable SFP+ footprint

+ Imininingwane ihambisana ne-SFF 8472

+ Ihambisana ne-SFP+ MSA ngesixhumi se-LC

+ Ukunikezwa kwamandla okukodwa okungu-3.3V

+ Ibanga lokushisa elisetshenziswayo lekesi:0°C kuya ku-70°C

+ Ukuchithwa kwamandla <1.5 W

Izinhlelo zokusebenza

+ 10GBASE-ER/EW & 10G Ethernet

Okujwayelekile

+ Ihambisana ne-SFF-8431

+ Ihambisana ne-SFF 8472

+ I-RoHS Iyahambisana.

Izilinganiso Eziphelele Eziphelele

Ipharamitha

Uphawu

Okuncane.

Thayipha.

Ubukhulu.

Iyunithi

Izinga Lokushisa Lokugcina

Ts

-40

-

85

ºC

Umswakama Ohlobene

RH

5

-

95

%

I-Voltage Yokuhlinzeka Amandla

VCC

-0.3

-

4

V

I-Signal Input Voltage

I-Vcc-0.3

-

Vcc+0.3

V

Izimo Zokusebenza Ezinconyiwe

Ipharamitha

Uphawu

Okuncane.

Thayipha.

Ubukhulu.

Iyunithi

Qaphela

I-Case Operating Temperature

Ticala

0

-

70

ºC

Ngaphandle kokugeleza komoya

I-Voltage Yokuhlinzeka Amandla

VCC

3.14

3.3

3.47

V

Ukunikezwa kwamandla kwamanje

I-ICC

-

450

mA

Isilinganiso Sedatha

BR

10.3125

Gbps

Ibanga lokudlulisela

TD

-

40

km

I-fiber ehlanganisiwe

I-fiber yemodi eyodwa

9/125um SMF

Izimpawu ze-Optical

Ipharamitha

Uphawu

Okuncane.

Thayipha.

Ubukhulu.

Iyunithi

Qaphela

I-Transmitter

Amandla Aqalisiwe Amaphakathi

PO

-1

+3

dBm

Inothi (1)

Isilinganiso Sokuqothula

ER

6

dB

I-Center Wavelength

λc

1530

1550

1565

nm

I-Spectrum Band Width (RMS)

σ

1.0

nm

I-SMSR

30

dB

I-Transmitter VALIWE Amandla Okukhiphayo

Pff

-30

dBm

I-Transmitter kanye Nesijeziso Sokusabalalisa

I-TDP

3.0

dB

Imaski yamehlo ephumayo

Ihambisana ne-IEEE 802.3ae

Umamukeli

Faka i-Optical Wavelength

λ

1270

1610

nm

Ukuzwela Komamukeli

Psen

-15.8

dBm

Inothi (2)

Amandla Okufaka Saturation (Ukugcwala ngokweqile)

I-Psat

0.5

dBm

I-LOS Detect -Bambisa Amandla

PA

-28

dBm

I-LOS Detect - Amandla Oshukela

PD

-19

dBm

I-LOS Thola i-Hysteresis

I-PHYS

0.5

dB

Qaphela:
1.Amandla ethuliwe (isilinganiso) amandla ahlanganiswe nefayibha yemodi eyodwa enesixhumi esiyinhloko. (Ngaphambi Kokuphila)
2.Kukalwa ngesignali yokuhlola ukuvumelana kwe-BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ

Izici zikagesi

Ipharamitha

Uphawu

Okuncane

Thayipha

Ubukhulu

Iyunithi

QAPHELA

Faka i-Voltage

Vcc

3.14

3.3

3.46

V

Ukunikezwa Kwamanje

Icc

450

mA

I-Transmitter

Okokufaka komehluko

Rin

100

Ω

1

Ukushwibeka kokufaka kwedatha okuphelile

Vin, pp

180

700

mV

Dlulisa Khubaza i-Voltage

VD

I-Vcc–1.3

Vcc

V

Dlulisa Vumela I-Voltage

I-VEN

Vee

I-Vee+ 0.8

V

2

Dlulisa Isikhathi Sokufaka Isicelo Sokukhubaza

10

us

Umamukeli

Ukushintsha kokuphuma kwedatha okuhlukile

Vuka, pp

300

850

mV

3

Isikhathi sokukhuphuka kokuphuma kwedatha

tr

28

ps

4

Isikhathi sokuwa kokukhishwa kwedatha

tf

28

ps

4

Iphutha le-LOS

Iphutha le-VLOS

I-Vcc–1.3

VccHOST

V

5

LOS Normal

I-VLOS evamile

Vee

Vee+0.8

V

5

Ukwenqatshwa Kokuhlinzekwa Kwamandla

I-PSR

100

mVpp

6

Amanothi:

  1. Ixhumeke ngqo kumaphini wokufaka wedatha we-TX. I-AC ihlanganiswe ngemuva kwalokho.
  2. Noma isifunda esivulekile.
  3. Ku-100 ohms ukunqanyulwa komehluko.
  4. 20 - 80%.
  5. Ukulahleka Kwesiginali yi-LVTTL. I-Logic 0 ikhombisa ukusebenza okuvamile; I-logic 1 ibonisa ukuthi akukho signali etholiwe.

Ukuzwela kwesamukeli kuthobelana nokusetshenziswa kwamandla kwe-sinusoidal modulation kuka-20 Hz kuya ku-1.5 MHz kuze kufike kunani elishiwo elisetshenziswa ngenethiwekhi yokuhlunga kagesi enconyiwe.

Phina Incazelo

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (1)

Phina

Uphawu

Igama/Incazelo

QAPHELA

1

VEET

I-Transmitter Ground (Ejwayelekile neGround Receiver)

1

2

TIPHUTHA

Iphutha Lokudlulisa.

2

3

TDIS

I-Transmitter Khubaza. Okukhipha i-laser kukhutshaziwe phezulu noma kuvuliwe.

3

4

I-SDA

Ulayini Wedatha Ye-Serial Interface enezintambo ezi-2

4

5

I-SCL

Ulayini wewashi wewashi elinezintambo ezi-2

4

6

MOD_ABS

Imojuli Abekho. Isekelwe ngaphakathi kwemojuli

4

7

RS0

Linganisa Khetha 0

5

8

LOS

Ukulahleka Kwenkomba Yesiginali. I-Logic 0 ibonisa ukusebenza okuvamile.

6

9

I-RS1

Alukho uxhumano oludingekayo

1

10

VEER

I-Receiver Ground (Ejwayelekile ne-Transmitter Ground)

1

11

VEER

I-Receiver Ground (Ejwayelekile ne-Transmitter Ground)

1

12

RD-

Umamukeli Uguqule IDATHA iphumile. I-AC ihlanganisiwe

13

I-RD+

Isamukeli I-DATA engaguquliwe iphumile. I-AC ihlanganisiwe

14

VEER

I-Receiver Ground (Ejwayelekile ne-Transmitter Ground)

1

15

VI-CCR

I-Receiver Power Supply

16

VI-CCT

I-Transmitter Power Supply

17

VEET

I-Transmitter Ground (Ejwayelekile neGround Receiver)

1

18

I-TD+

I-Transmitter I-DATA Engaguquliwe ngaphakathi. I-AC Ihlanganisiwe.

19

TD-

I-Transmitter Inverted DATA in. I-AC Ihlanganisiwe.

20

VEET

I-Transmitter Ground (Ejwayelekile neGround Receiver)

1

Amanothi:

  1. Inkundla yesifunda ihlukanisiwe ngaphakathi ne-chassis.
  2. TIPHUTHAingumqoqi ovulekile/okukhipha amanzi, okufanele kudonswe nge-4.7k – 10k Ohms resistor ebhodini lomsingathi uma kuhloselwe ukusetshenziswa. I-voltage yokudonsela phezulu kufanele ibe phakathi kuka-2.0V ukuya ku-Vcc + 0.3VA okukhiphayo okuphezulu kubonisa iphutha lesidluliseli elibangelwa amandla amanje okuchema kwe-TX noma amandla okukhiphayo e-TX edlula imingcele ye-alamu esethiwe. Okukhiphayo okuphansi kubonisa ukusebenza okuvamile. Esimeni esiphansi, okukhiphayo kudonselwa ku-<0.8V.
  3. Okukhipha i-laser kukhutshaziwe ku-TDIS>2.0V noma ivuliwe, inikwe amandla ku-TDIS<0.8V.
  4. Kufanele idonswe ngebhodi lokusingatha elingu-4.7kΩ- ​​10kΩ ku-voltage ephakathi kuka-2.0V no-3.6V. I-MOD_ABS idonsa umugqa uphansi ukuze ibonise ukuthi imojuli ixhunyiwe.
  5. Ngaphakathi kudonswe phansi nge-SFF-8431 Rev 4.1.
  6. I-LOS iwukukhipha komqoqi ovulekile. Kufanele idonswe ngo-4.7kΩ – 10kΩ ebhodini lomsingathi ibe ngugesi ophakathi kuka-2.0V no-3.6V. I-Logic 0 ikhombisa ukusebenza okuvamile; i-logic 1 ibonisa ukulahlekelwa kwesignali.

Digital Diagnostic Imisebenzi

Ama-transceivers e-OP-SFP+-ER asekela i-2-wire serial communication protocol njengoba kuchazwe ku-SFP+MSA.

I-serial ID ejwayelekile ye-SFP inikeza ukufinyelela olwazini lokuhlonza oluchaza amandla womdluliseli, ukuxhumana okujwayelekile, umkhiqizi, nolunye ulwazi.

Ukwengeza, ama-transceivers e-SFP + anikeza isikhombimsebenzisi esiyingqayizivele esithuthukisiwe sokuqapha ukuxilonga kwedijithali, okuvumela ukufinyelela kwesikhathi sangempela kumingcele yokusebenza kwedivayisi njengokushisa kwe-transceiver, i-laser bias current, amandla optical adlulisiwe, ithole amandla optical kanye ne-transceiver supply voltage. Iphinde ichaze isistimu eyinkimbinkimbi ye-alamu namafulegi asexwayiso, axwayisa abasebenzisi bokugcina lapho amapharamitha athile okusebenza angaphandle kwebanga elijwayelekile lesethi yefekthri.

I-SFP MSA ichaza imephu yememori yamabhayithi angu-256 ku-EEPROM efinyeleleka ngaphezu kokuxhumana kwe-serial yezintambo ezingu-2 kukheli le-8 bit 1010000X (A0h).Isixhumi esibonakalayo sokuqapha ukuxilonga kwedijithali sisebenzisa ikheli le-8 bit 1010001X (A2h), ngakho-ke imephu yememori ye-serial echazwe ekuqaleni ihlala ingashintshiwe.

Ulwazi olusebenzayo nolokuxilonga luyagadwa futhi lubikwe I-Digital Diagnostics Transceiver Controller (DDTC) ngaphakathi kwe-transceiver, efinyelelwa nge-serial interface enezintambo ezi-2. Uma iphrothokholi ye-serial yenziwa isebenze, isignali yewashi lomkhiqizo (SCL, Mod Def 1) ikhiqizwa umsingathi. Unqenqema oluphozithivu luwashi idatha ku-transceiver ye-SFP kulawo masegimenti e-E2PROM angavikelekile ngokubhala. Unqenqema olunegethivu lwewashi idatha evela ku-transceiver ye-SFP. Isiginali yedatha yomkhiqizo (i-SDA, i-Mod Def 2) inamacala amabili okudlulisa idatha ye-serial. Umsingathi usebenzisa i-SDA ngokuhlanganyela ne-SCL ukumaka ukuqala nesiphetho sokwenziwa kusebenze kwephrothokholi yochungechunge. Izinkumbulo zihlelwa njengochungechunge lwamagama edatha angu-8-bit angabhekwa ngawodwana noma ngokulandelana.

Kunconyiwe I-Interface Circuit

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (2)

Ubukhulu bohlaka

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (3)

Ukuthobela Umthetho

Isici

Ireferensi

Ukusebenza

Ukukhishwa kwe-Electrostatic (ESD)

I-IEC/EN 61000-4-2

Iyahambisana namazinga

I-Electromagnetic Interference (EMI)

I-FCC Ingxenye 15 Ikilasi B EN 55022 Ikilasi B (CISPR 22A)

Iyahambisana namazinga

I-Laser Eye Safety

I-FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Umkhiqizo we-laser we-Class 1

I-ROHS

2002/95/EC

Iyahambisana namazinga

I-EMC

I-EN61000-3

Iyahambisana namazinga

Isithasiselo A. Ukubuyekezwa Kombhalo

Inguqulo No.

Usuku

Incazelo

1.0

2010-09-01

Idatha yokuqala

2.0

2011-09-10

Buyekeza ifomethi kanye nelogo yenkampani

3.0

2012-08-03

Buyekeza i-spec yamandla -1~4 ukuze -1~3


  • Okwedlule: