I-transceiver ye-SFP (Small Form-factor Pluggable) isebenzisa isiteshi esisodwa ukudlulisa nokwamukela idatha I-QSFP (i-Quad Small Form-factor Pluggable) ihlanganisa iziteshi ezine zibe yimojuli eyodwa ukuze ifinyelele i-bandwidth ephindwe kane.
I-SFP (Umzila O-1): Inendawo encane yokubeka uphawu enomzila owodwa wokudlulisa (i-Tx) nokwamukela (i-Rx). Ngokuvamile isebenzisa izixhumi ze-LC duplex noma ze-SC simplex. I-QSFP (Imizila emi-4): Inendawo ebanzi. Ineziteshi ezine zokudlulisa ezizimele kanye neziteshi ezine zokwamukela ezizimele. Ngokuvamile isebenzisa izixhumi ze-MPO/MTP ezixinene kakhulu (ze-parallel optics) noma i-multiplexer yangaphakathi phezu kwe-LC duplex (ye-Wavelength Division Multiplexing).
Isici Sefomu Amanani Edatha Eyinhloko Izindinganiso Ezivamile / Izinhlobo Amacala Okusetshenziswa Okuvamile
I-SFP 1 Gbps I-1G SFP Izixhumanisi zebhizinisi elidala
I-SFP+ 10 Gbps 10G SFP+ Ama-core ebhizinisi lanamuhla
I-SFP28 25 Gbps 25G SFP28 Izikhungo zedatha ze-5G FTTA /
I-SFP56 50 Gbps 50G SFP56 Ikhompyutha engenantambo ephakathi nendawo, ekhethekile
I-QSFP+ 40 Gbps (4 x 10G) Isisekelo se-40G-SR4 / LR4 Izendlalelo zokusatshalaliswa kwebhizinisi
QSFP28 100 Gbps (4 x 25G) Isisekelo se-100G-SR4 / LR4 Izindwangu zesikhungo sedatha ezihlanganisa amaqabunga nomgogodla
I-QSFP56 200 Gbps (4 x 50G) 200G FR4 / DR4 Amaqoqo e-AI kanye nengqalasizinda yamafu
I-KCO-GLC-EX-SMD 1000BASE-EX SFP 1310nm 40km DOM Duplex LC SMF Fiber Optic Transceiver Module

I-KCO-GLC-EX-SMD 1000BASE-EX SFP 1310nm 40km DOM Duplex LC SMF Fiber Optic Transceiver Module

- Izixhumanisi Zedatha Ezifika Ku-1.25Gb/s

- Okushisayo-Okungaxhunywa

- Umthumeli we-laser we-DFB ongu-1310nm

- Isixhumi se-Duplex LC

- Kufika kumakhilomitha angu-40 ku-9/125μm SMF

- Ukunikezwa Kwamandla Okukodwa +3.3V

- Ukushabalalisa amandla aphansi <1W ngokuvamile

- Izinga lokushisa lokusebenza kwezentengiselwano: 0°C kuya ku-70°C

- Ukuthobela i-RoHS

- Iyahambisana ne-SFF-8472

I-Transceiver ye-SFP yemodi eyodwa engu-1.25Gb/s engu-1310nm

I-Transceiver ye-SFP yemodi eyodwa engu-1.25Gb/s engu-1310nm

Ama-transceiver e-Small Form Factor Pluggable (SFP) ayahambisana ne-Small Form Factor Pluggable Multi-Sourcing Agreement (MSA). I-transceiver inezigaba ezine: umshayeli we-LD, i-amplifier ekhawulelayo, i-FP laser kanye ne-PIN photo-detector. Idatha yemojuli ixhumanisa kufika ku-20km ku-9/125um single mode fiber.

Ukukhishwa kwe-optical kungavinjelwa ngokufaka kwe-TTL logic okusezingeni eliphezulu kwe-Tx Disable. I-Tx Fault inikezwa ukukhombisa lokho kwehla kwe-laser. Ukulahlekelwa kokukhishwa kwesignali (LOS) kunikezwa ukukhombisa ukulahleka kwesignali ye-optical yokufaka yomamukeli noma isimo sesixhumanisi nomlingani.

I-Transceiver ye-SFP yemodi eminingi engu-1.25Gb/s engu-850nm

I-Transceiver ye-SFP yemodi eminingi engu-1.25Gb/s engu-850nm

Ama-transceiver e-KCO-SFP-MM-1.25-550-01 Small Form Factor Pluggable (SFP) ayahambisana ne-Small Form Factor Pluggable Multi-Sourcing Agreement (MSA).

I-transceiver inezigaba ezine: umshayeli we-LD, i-amplifier ekhawulelayo, i-laser ye-VCSEL kanye ne-PIN photo-detector. Idatha yemojuli ixhumanisa kufika ku-550m ku-50/125um multimode fiber.

Ukukhishwa kwe-optical kungavinjelwa ngokufaka kwe-TTL logic okusezingeni eliphezulu kwe-Tx Disable. I-Tx Fault inikezwa ukukhombisa lokho kwehla kwe-laser. Ukulahlekelwa kokukhishwa kwesignali (LOS) kunikezwa ukukhombisa ukulahleka kwesignali ye-optical yokufaka yomamukeli noma isimo sesixhumanisi nomlingani.

I-KCO SFP GE T 1000M 1.25G RJ45 Isixhumi Sethusi Esiyi-100m Imojula Yesidlulisi Se-Optical

I-KCO SFP GE T 1000M 1.25G RJ45 Isixhumi Sethusi Esiyi-100m Imojula Yesidlulisi Se-Optical

I-KCO SFP GE T 1000M 1.25G RJ45 Isixhumi Sethusi Esingu-30m Imojuli Yesidlulisi Se-Optical

iyahambisana ne-Cisco GLC-T / GLC-TE/SFP-GE-T, Mikrotik S-RJ01

I-KCO SFP GE T iyimojuli ye-transceiver yethusi ehambisana ne-Cisco SFP-GE-T eklanywe, yahlelwa futhi yahlolwa ukuze isebenze nama-switch nama-router omkhiqizo we-Cisco. Ihlinzeka ngokuxhumeka okuthembekile kwe-1GbE (1000 Mbps) ngekhebula lethusi, kumanethiwekhi ahambisana ne-1000BASE-T, enebanga eliphakeme elifika ku-100 m.

I-KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

I-KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

I-KCO SFP+ 10G ER iyindinganiso yezintambo ze-10 Gigabit Ethernet phezu kwe-fiber optic, ezenzelwe ngqo ukudlulisa ibanga elide.

Ivumela ukudluliswa kwedatha kufika kumakhilomitha angu-40 ngaphezulu kwe-fiber yemodi eyodwa (i-SMF) ngobude be-wavelength obungu-1550nm.

Amamojula e-fiber optic e-KCO SFP+ 10G ER, avame ukusetshenziswa njengama-transceiver e-SFP+, asetshenziswa ezinhlelweni ezahlukahlukene lapho kudingeka khona ukufinyelela okwengeziwe, njengokuxhuma izakhiwo ekhampasi enkulu noma ngaphakathi kwenethiwekhi yendawo yedolobha.

I-Transceiver ye-10Gb/s SFP+ Hot Pluggable, i-Duplex LC, +3.3V, i-1310nm DFB/PIN, Imodi eyodwa, i-10km

I-Transceiver ye-10Gb/s SFP+ Hot Pluggable, i-Duplex LC, +3.3V, i-1310nm DFB/PIN, Imodi eyodwa, i-10km

I-KCO-SFP+-10G-LR iyimoduli ye-transceiver ye-optical engu-10Gb/s encane kakhulu yezinhlelo zokusebenza zokuxhumana ze-optical ezilandelanayo ku-10Gb/s, eguqula phakathi umfudlana wedatha kagesi we-10Gb/s olandelanayo nesignali ye-optical engu-10Gb/s.

I-KCO-SFP+-SR 10Gb/s 850nm Multi-mode SFP+ Transceiver

I-KCO-SFP+-SR 10Gb/s 850nm Multi-mode SFP+ Transceiver

Kufika ku-11.1Gbps Izixhumanisi Zedatha
Ukudluliselwa kwejubane kufika ku-300m ku-MMF
Ukushabalalisa amandla < 1W
I-VSCEL laser kanye ne-PIN receiver
I-Metal evalwe, ye-EMI ephansi
Isixhumi esibonakalayo esinezintambo ezimbili esinokuqapha okuhlanganisiwe kweDijithali Yokuhlola
Unyawo lwe-SFP+ olushelelayo olushisayo
Imininingwane ihambisana ne-SFF 8472
Ihambisana ne-SFP+ MSA ene-LC connector
Ukunikezwa kwamandla okukodwa okungu-3.3V
Ububanzi bokushisa kokusebenza kwekesi: 0°C kuya ku-70°C

I-KCO-25G-SFP28-LR 25Gb/s BIDI SFP28 SM 10KM Transceiver

I-KCO-25G-SFP28-LR 25Gb/s BIDI SFP28 SM 10KM Transceiver

OyedwaIsixhumi se-LCUsekelophezuluto 2Amanani we-bit angu-5Gb/s

Ihambisana ne-SFP28 MSA

I-interface kagesi ihambisana ne-SFF-8431

I-SFP eshelelayo28unyawo

Imisebenzi yokuxilonga yedijithali eyakhelwe ngaphakathi

Kufika ku-10 km ku-9/125um SMF G.652

Ukunikezwa kwamandla okukodwa okungu-3.3V

Ihambisana ne-RoHS6/6

Umkhiqizo we-laser wekilasi 1 uhambisana ne-EN 60825-1

Ububanzi bokushisa bokusebenza:0kuya ku-70/-40℃ kuya ku-85

Ukusetshenziswa kwamandla <1.2W

I-KCO-25G-SFP28-SR LC Duplex 850nm 100m MMF 25Gb/s 850nm I-Multi-mode SFP28 Transceiver

I-KCO-25G-SFP28-SR LC Duplex 850nm 100m MMF 25Gb/s 850nm I-Multi-mode SFP28 Transceiver

Kufika ku-25Izixhumanisi Zedatha ze-Gbps
Ubude obukhulu besixhumanisi sezixhumanisi ezingama-70m kuzixhumanisi ze-OM3 noma eziyi-100m ku-fiber ye-OM4 multimode
Ukushabalalisa amandla < 1W
I-VSCEL laser kanye ne-PIN receiver
I-Metal evalwe, ye-EMI ephansi
Isixhumi esibonakalayo esinezintambo ezimbili esinokuqapha okuhlanganisiwe kweDijithali Yokuhlola
Unyawo lwe-SFP28 olushelelayo olushisayo
Imininingwane ihambisana ne-SFF 8472
Ihambisana ne-SFP28 MSA ene-LC connector
Ukunikezwa kwamandla okukodwa okungu-3.3V
Ububanzi bokushisa kokusebenza kwekesi: Kwezentengiselwano: 0°C kuya ku-+70°C

I-KCO QSFP+ 40G ER4 40Gb/s QSFP+ SMF 1310 40km Transceiver

I-KCO QSFP+ 40G ER4 40Gb/s QSFP+ SMF 1310 40km Transceiver

Imizila emi-4 ye-CWDM design Mux/Demux

Kufika ku-11.1Gbps Izinga ledatha ngobude be-wavelength

Ukudluliselwa kwemoto okufika kumakhilomitha angu-40 ku-SMF ene-FEC.

Ingaxhunywa ngogesi ngokushisa

Isixhumanisi Sokuqapha Ukuxilongwa Kwedijithali

Ihambisana ne-QSFP+ MSA ene-LC connector

Ububanzi bokushisa kokusebenza kwekesi: 0°C kuya ku-70°C

Ukushabalalisa amandla < 3.5 W

I-KCO QSFP+ 40G LR4 LC 40Gb/s QSFP+ LR4 SMF 10km LC Transceiver

I-KCO QSFP+ 40G LR4 LC 40Gb/s QSFP+ LR4 SMF 10km LC Transceiver

Kuyini i-QSFP+ 40G LR4

I-40G QSFP+ LR4 iyi-module ye-transceiver ye-optical ekwazi ukuxhunywa eshisayo ye-40 Gigabit Ethernet (40GbE) esebenzisa i-fiber yemodi eyodwa ukudlulisa idatha efinyelela kumakhilomitha ayi-10. Isebenza ngokuhlanganisa iziteshi ezine ezihlukene ze-10G emicu emibili ye-fiber yemodi eyodwa kusetshenziswaUbuchwepheshe be-CWDM, bese ihlukaniswa ibe yiziteshi ezine ze-10G ekugcineni kokwamukela. Le module yaziwa ngokuxhumeka kwayo okunobukhulu obuphezulu, isici esincane sefomu.

I-KCO QSFP+ 40G PLR4 SMF 1310 10km MPO 40GBASE PSM4 LR PLR4 QSFP+ SMF 1310nm 10km MTP/MPO Isixhumi se-Optical Transceiver Module

I-KCO QSFP+ 40G PLR4 SMF 1310 10km MPO 40GBASE PSM4 LR PLR4 QSFP+ SMF 1310nm 10km MTP/MPO Isixhumi se-Optical Transceiver Module

* Iyahambisana ne-QSFP MSA

* Ukunikezwa kwamandla okukodwa +3.3V

* Izinga lokushisa lokusebenza kwezentengiselwano: 0oC kuya ku-+70oC

* Isixhumi se-MPO/MTP

* Ihambisana ne-RoHS

Ukusetshenziswa kwe-SFP ne-QSFP ku-FTTH kanye ne-FTTA Solution

I-Metric Yokuklama I-FTTH (I-Fiber-to-the-Home) I-FTTA (I-Fiber-to-the-Antenna)
Imojuli Yomphetho (i-SFP) I-GPON / XGS-PON SFP (i-Simplex SC) I-25G SFP28 eCPRI (i-Duplex noma i-BiDi LC)
Imojuli Eyinhloko (i-QSFP) Izixhumanisi zenethiwekhi ze-QSFP28 / QSFP-DD Ukuqhekeka Komsakazo we-QSFP28 Port-to-SFP28
Iphrothokholi Eyinhloko Ukufakwa kwe-Ethernet / ATM I-CPRI (4G) / i-eCPRI (5G Ifakwe Ephaketheni)
Isidingo Sesikhashana Ezentengiselwano (0°C kuya ku-70°C) ngaphakathi kwe-CO2 Izimboni (-40°C kuya ku-85°C) phezulu kwensika
Ukusetshenziswa [Ihhovisi Eliphakathi OLT] ===( Isixhumanisi Sokukhuphuka se-QSFP)===> [ I-Core Switch ]
|
(I-PON SFP)
|
[ I-Passive Splitter ] ——> [ Ikhaya ONT / ONU ]
[ I-BBU Hub / DU ] ===( Ukuqhekeka kwe-QSFP28 )===> [ Amachweba e-Tower e-SFP28 angu-4x ]
||
(Isiqu Esiqondile)
||
[25G SFP28 RRU]
Amanethiwekhi e-FTTH athembele kakhulu kuma-topology e-Passive Optical Network (PON) ukuze asabalalise i-inthanethi kusuka eHhovisi Eliphakathi (CO) iye emakhaya ngabanye I-SFP28 (25G) Standard: Amaseli e-Macro esimanje e-5G asebenza kuma-transceiver e-25G SFP28 akhelwe ngqo amaphrothokholi e-eCPRI (Enhanced Common Public Radio Interface).
Uhlangothi lwe-OLT: I-chassis ye-Optical Line Terminal (OLT) isebenzisa amamojula akhethekile e-PON SFP (GPON, XGS-PON, noma i-25G-PON). Lawa ahlukile ngoba angama-BiDi (Bidirectional) simplex SFPs—asebenzisa isixhumi se-SC esisodwa ukudlulisa ngobude be-wavelength eyodwa (isb., 1490nm) bese ethola kwenye (isb., 1310nm) ukuze akhonze amakhaya afinyelela ku-32 noma angu-64 phezu komucu owodwa wefayibha. Ukuqina Kwezimboni: Ama-SFT abekwe phezulu embhoshongweni kumele alinganiswe ngokushisa kwezimboni (-40°C kuya ku-85°C) ukuze asinde esimweni sezulu esibi kakhulu sesizini. Ahlanganiswe nezindlu zangaphandle eziqinile njenge-FullAXS noma i-ODVA ngaphambi kokuba axhunywe ngqo kwi-Remote Radio Unit (RRU)
Uhlangothi lwe-ONT/ONU: Itheminali yenethiwekhi ye-optical eseceleni kweklayenti ngaphakathi kwekhaya noma ebhizinisini ivame ukusebenzisa amamojula ajwayelekile e-1G SFP noma e-10G SFP+ axhunywe esangweni lendawo yokuhlala. I-BiDi kanye ne-CWDM: Ukuze bonge isisindo kanye nezinsiza zefayibha empahleni yombhoshongo, ochwepheshe bavame ukusebenzisa amamojula e-BiDi SFP28 noma e-CWDM SFP28, okuvumela ama-frequency band amaningi ukuthi abelane ngemicu embalwa yengilazi.
Ukusetshenziswa kwe-QSFP (I-Central Office Core: Abasebenzisi basekhaya abasebenzisi amamojula e-QSFP. Esikhundleni salokho, ama-transceiver e-QSFP28 (100G) noma e-QSFP-DD (400G/800G) asetshenziswa ngaphakathi kwe-Central Office. Ahlanganisa ithrafikhi enkulu ehlanganisiwe evela kumakhadi amaningi e-PON SFP bese eyihambisa iye phezulu enkabeni ye-inthanethi ebanzi. Ukufakwa Kokuqhekeka: Esikhundleni sokusebenzisa izintambo ze-SFP ezingama-24 ngazinye, i-router ye-baseband enamandla aphezulu izosebenzisa amachweba e-QSFP28 (100G) kwimodi yokuqhekeka. Ichweba elilodwa le-QSFP28 lixhumanisa nekhebula le-trunk le-MPO eliphuma ku-1 kuya ku-4, liletha ngempumelelo iziteshi ezine ezizimele ze-25G eCPRI eziqondile ezifinyelela kumarediyo amane ahlukene.

Inqubo
Inqubo
Inqubo