I-KCO-Fiver-MTP-MPO-QSFP-Banner-page-1

I-KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

Incazelo emfushane:

I-KCO SFP+ 10G ER iyindinganiso yezintambo ze-10 Gigabit Ethernet phezu kwe-fiber optic, ezenzelwe ngqo ukudlulisa ibanga elide.

Ivumela ukudluliswa kwedatha kufika kumakhilomitha angu-40 ngaphezulu kwe-fiber yemodi eyodwa (i-SMF) ngobude be-wavelength obungu-1550nm.

Amamojula e-fiber optic e-KCO SFP+ 10G ER, avame ukusetshenziswa njengama-transceiver e-SFP+, asetshenziswa ezinhlelweni ezahlukahlukene lapho kudingeka khona ukufinyelela okwengeziwe, njengokuxhuma izakhiwo ekhampasi enkulu noma ngaphakathi kwenethiwekhi yendawo yedolobha.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

I-KCO-SFP+-10G-ER

+ I-KCO SFP+ 10G ER iyindinganiso yezintambo ze-10 Gigabit Ethernet phezu kwe-fiber optic, ezenzelwe ngqo ukudlulisa ibanga elide.

+ Ivumela ukudluliswa kwedatha kufika kumakhilomitha angu-40 ngaphezulu kwefayibha yemodi eyodwa (i-SMF) ngobude be-wavelength obungu-1550nm.

Amamojula e-fiber optic e-+KCO SFP+ 10G ER, avame ukusetshenziswa njenge-SFP+ transceivers, asetshenziswa ezinhlelweni ezahlukene lapho kudingeka khona ukufinyelela okwengeziwe, njengokuxhuma izakhiwo ekhampasi enkulu noma ngaphakathi kwenethiwekhi yendawo yedolobha.

Izici Zomkhiqizo

+ Kufika ku-11.1Gbps Izixhumanisi Zedatha

+ Ukudluliselwa kwejubane kufika ku-40km ku-SMF

+ Umthumeli we-EML kanye nomemukeli we-PIN

+ Isembozo sensimbi, se-EMI ephansi

+ isikhombimsebenzisi esinezintambo ezimbili esinokuqapha okuhlanganisiwe kweDijithali Yokuhlola

+ Unyawo lwe-SFP+ olushelelayo olushisayo

+ Imininingwane ihambisana ne-SFF 8472

+ Ihambisana ne-SFP+ MSA ene-LC connector

+ Ukunikezwa kwamandla okukodwa okungu-3.3V

+ Ububanzi bokushisa kokusebenza kwekesi: 0°C kuya ku-70°C

+ Ukushabalalisa amandla < 1.5 W

Izicelo

+ 10GBASE-ER/EW & 10G Ethernet

Okujwayelekile

+ Iyahambisana ne-SFF-8431

+ Ihambisana ne-SFF 8472

+ Ihambisana ne-RoHS.

Izilinganiso Eziphezulu Kakhulu

Ipharamitha

Uphawu

Okungenani.

Uhlobo.

Ubukhulu.

Iyunithi

Izinga Lokushisa Lesitoreji

Ts

-40

-

85

ºC

Umswakama Olinganiselwe

RH

5

-

95

%

I-Voltage Yokunikezwa Kwamandla

I-VCC

-0.3

-

4

V

I-Voltage yokufaka yesignali

I-Vcc-0.3

-

I-Vcc+0.3

V

Izimo Zokusebenza Ezinconyiwe

Ipharamitha

Uphawu

Okungenani.

Uhlobo.

Ubukhulu.

Iyunithi

Inothi

Izinga Lokushisa Lokusebenza Lekesi

Ticala

0

-

70

ºC

Ngaphandle kokugeleza komoya

I-Voltage Yokunikezwa Kwamandla

I-VCC

3.14

3.3

3.47

V

Ukunikezwa Kwamandla Kwamanje

I-ICC

-

450

mA

Izinga Ledatha

BR

10.3125

I-Gbps

Ibanga Lokudlulisa

TD

-

40

km

I-fibre ehlanganisiwe

I-fibre yemodi eyodwa

9/125um SMF

Izici Zokubona

Ipharamitha

Uphawu

Okungenani.

Uhlobo.

Ubukhulu.

Iyunithi

Inothi

Umthumeli

Amandla Aphakathi Aqalisiwe

PO

-1

+3

i-dBm

Inothi (1)

Isilinganiso Sokuphela

ER

6

dB

Ubude Begagasi Eliphakathi

λc

1530

1550

1565

nm

Ububanzi bebhendi ye-Spectrum (RMS)

σ

1.0

nm

I-SMSR

30

dB

Amandla Okukhipha Okudluliswayo OVALIWE

I-PFoff

-30

i-dBm

Isijeziso Sokudlulisa Nokuhlakazeka

I-TDP

3.0

dB

Imaski Yamehlo Ephumayo

Ihambisana ne-IEEE 802.3ae

Umamukeli

Ukufaka i-Optical Wavelength

λ

1270

1610

nm

Ukuzwela Komamukeli

I-Psen

-15.8

i-dBm

Inothi (2)

Amandla Okugcwalisa Okufakwayo (Ukulayisha Okungaphezu Kokujwayelekile)

I-Psat

0.5

i-dBm

Amandla Okuqinisekisa e-LOS Detect

PA

-28

i-dBm

I-LOS Detect - Amandla e-Deassert

PD

-19

i-dBm

I-LOS Thola i-Hysteresis

I-PHYS

0.5

dB

Qaphela:
1. Amandla aqalisiwe (isilinganiso) amandla ahlanganiswe kwi-fiber yemodi eyodwa ene-connector enkulu. (Ngaphambi Kokuphila)
2. Kulinganiswe ngesignali yokuhlola ukuhambisana kwe-BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ

Izici Zikagesi

Ipharamitha

Uphawu

Ubuncane

Uhlobo

Ubuningi

Iyunithi

QAPHELA

I-Voltage Yokunikezela

I-Vcc

3.14

3.3

3.46

V

Ukunikezwa Kwamanje

I-Icc

450

mA

Umthumeli

Ukufakwa komehluko wokufaka

Rin

100

Ω

1

Ukushintsha kokufaka kwedatha okuphele okukodwa

Vin,pp

180

700

mV

Dlulisa Khubaza I-Voltage

VD

I-Vcc–1.3

I-Vcc

V

Dlulisa Vumela I-Voltage

I-VEN

Vee

I-Vee+ 0.8

V

2

Isikhathi Sokuqinisekisa Sokukhubaza Sokudlulisa

10

us

Umamukeli

Ukushintshashintsha kokukhipha idatha okuhlukile

Vout,pp

300

850

mV

3

Isikhathi sokukhuphuka kokukhipha idatha

tr

28

ps

4

Isikhathi sokuwa kokukhipha idatha

tf

28

ps

4

Iphutha le-LOS

Iphutha le-VLOS

I-Vcc–1.3

I-VccHOST

V

5

I-LOS Normal

Isilinganiso se-VLOS

Vee

I-Vee+0.8

V

5

Ukwenqatshwa Kokunikezwa Kwamandla

I-PSR

100

i-mVpp

6

Amanothi:

  1. Kuxhunywe ngqo kumaphini okufaka idatha e-TX. I-AC ihlanganiswe ngemva kwalokho.
  2. Noma isekethe evulekile.
  3. Ukuqeda umehluko ku-100 ohms.
  4. 20 – 80%.
  5. Ukulahleka Kwesignali kuyi-LVTTL. I-Logic 0 ikhombisa ukusebenza okuvamile; i-logic 1 ikhombisa ukuthi akukho signali etholakele.

Ukuzwela kwe-receiver kuhambisana nokuguqulwa kwe-sinusoidal yokunikezwa kwamandla kagesi okungu-20 Hz kuya ku-1.5 MHz kuze kufike enanini elicacisiwe elisetshenziswa ngenethiwekhi yokuhlunga yokunikezwa kwamandla enconyiwe.

Incazelo yephinikhodi

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (1)

Iphinikhodi

Uphawu

Igama/Incazelo

QAPHELA

1

VI-EET

Indawo Yokudlulisa (Ejwayelekile Nendawo Yokwamukela)

1

2

TIphutha

Iphutha Lomthumeli.

2

3

TI-DIS

Ukukhubaza i-Transmitter. Ukukhishwa kwe-laser kukhutshaziwe uma kuvuliwe noma kuphezulu.

3

4

I-SDA

Umugqa Wedatha Yesixhumi Esihlanganisiwe Esinezintambo Ezimbili

4

5

I-SCL

Umugqa Wewashi Le-Serial Interface Elinezintambo Ezimbili

4

6

I-MOD_ABS

Imojuli Ayisekho. Isekelwe ngaphakathi kwemojuli

4

7

I-RS0

Khetha Izinga 0

5

8

I-LOS

Ukulahlekelwa yinkomba yesignali. I-Logic 0 ikhombisa ukusebenza okuvamile.

6

9

I-RS1

Akukho ukuxhumana okudingekayo

1

10

VI-EER

Indawo Yokwamukela (Ejwayelekile Nendawo Yokudlulisa)

1

11

VI-EER

Indawo Yokwamukela (Ejwayelekile Nendawo Yokudlulisa)

1

12

RD-

I-Receiver Inverted DATA iphumile. I-AC ihlanganisiwe

13

RD+

Umamukeli I-DATA Engaguquliwe iphumile. I-AC Ehlanganisiwe

14

VI-EER

Indawo Yokwamukela (Ejwayelekile Nendawo Yokudlulisa)

1

15

VI-CCR

Ukunikezwa Kwamandla Okwamukela

16

VI-CCT

Ukunikezwa Kwamandla Okudlulisa

17

VI-EET

Indawo Yokudlulisa (Ejwayelekile Nendawo Yokwamukela)

1

18

I-TD+

I-Transmitter Non-Inverted DATA in. I-AC Ehlanganisiwe.

19

I-TD-

I-Transmitter Inverted DATA ku-AC Ehlanganisiwe.

20

VI-EET

Indawo Yokudlulisa (Ejwayelekile Nendawo Yokwamukela)

1

Amanothi:

  1. Inhlabathi yesekethe ihlukaniswe ngaphakathi nomhlabathi we-chassis.
  2. TIphuthakuyi-open collector/drain output, okufanele idonswe phezulu nge-resistor engu-4.7k – 10k Ohms ebhodini lokusingatha uma ihloselwe ukusetshenziswa. I-voltage yokudonsa kufanele ibe phakathi kuka-2.0V kuya ku-Vcc + 0.3VA high output ikhombisa iphutha lokudlulisela elibangelwa yi-TX bias current noma amandla okukhipha e-TX adlula imingcele ye-alamu esethiwe. Ukukhipha okuphansi kubonisa ukusebenza okuvamile. Esimweni esiphansi, umphumela udonswa uye ku-<0.8V.
  3. Ukukhishwa kwe-laser kukhutshaziwe ku-TI-DIS>2.0V noma ivuliwe, ivuliwe ku-TI-DIS<0.8V.
  4. Kufanele idonswe phezulu ngebhodi lokusingatha elingu-4.7kΩ- ​​10kΩ ku-voltage ephakathi kuka-2.0V no-3.6V. I-MOD_ABS idonsa umugqa ophansi ukuze ikhombise ukuthi imojuli ixhunyiwe.
  5. Kudonswe phansi ngaphakathi ngokwe-SFF-8431 Rev 4.1.
  6. I-LOS iwumkhiqizo ovulekile wokuqoqa. Kufanele idonswe phezulu nge-4.7kΩ - 10kΩ ebhodini lokusingatha ku-voltage ephakathi kuka-2.0V no-3.6V. I-Logic 0 ikhombisa ukusebenza okuvamile; i-logic 1 ikhombisa ukulahleka kwesignali.

Imisebenzi Yokuxilonga Yedijithali

Ama-transceiver e-OP-SFP+-ER asekela iphrothokholi yokuxhumana ye-serial enezintambo ezimbili njengoba ichazwe ku-SFP+MSA.

I-ID ejwayelekile ye-serial ye-SFP inikeza ukufinyelela kolwazi lokuhlonza oluchaza amakhono e-transceiver, izixhumi ezijwayelekile, umenzi, nolunye ulwazi.

Ngaphezu kwalokho, ama-transceiver e-SFP+ ahlinzeka nge-interface yokuqapha yokuxilonga yedijithali ethuthukisiwe ehlukile, evumela ukufinyelela ngesikhathi sangempela kumapharamitha okusebenza kwedivayisi njengokushisa kwe-transceiver, i-laser bias current, amandla okukhanya adluliselwe, amandla okukhanya atholiwe kanye ne-voltage yokunikezwa kwe-transceiver. Iphinde ichaze uhlelo oluyinkimbinkimbi lwamafulegi e-alamu kanye nesexwayiso, oluxwayisa abasebenzisi bokugcina lapho amapharamitha athile okusebenza engaphandle kwebanga elijwayelekile elibekwe efektri.

I-SFP MSA ichaza imephu yememori engu-256-byte ku-EEPROM efinyeleleka nge-interface ye-serial enezintambo ezimbili ekhelini le-8 bit 1010000X (A0h). I-interface yokuqapha ukuxilongwa kwedijithali isebenzisa ikheli le-8 bit 1010001X (A2h), ngakho-ke imephu yememori ye-serial ID echazwe ekuqaleni ayishintshi.

Ulwazi lokusebenza nokuxilongwa luqashwe futhi lubikwe yi-Digital Diagnostics Transceiver Controller (DDTC) ngaphakathi kwe-transceiver, efinyelelwa nge-interface ye-serial enezintambo ezimbili. Uma i-protocol ye-serial ivuliwe, isignali yewashi le-serial (SCL, Mod Def 1) ikhiqizwa yi-host. I-positive edge iwasha idatha ku-transceiver ye-SFP kulezo zingxenye ze-E2PROM ezingavikelwe ngokubhala. I-negative edge iwasha idatha evela ku-transceiver ye-SFP. Isignali yedatha ye-serial (SDA, Mod Def 2) iqondiswa kabili ekudlulisweni kwedatha ye-serial. I-host isebenzisa i-SDA ngokubambisana ne-SCL ukuphawula ukuqala nokuphela kokusebenza kwe-protocol ye-serial. Izinkumbulo zihlelwe njengochungechunge lwamagama edatha angu-8-bit angabhekwana ngawodwana noma ngokulandelana.

Isekethe Yesixhumi Esiphakanyisiwe

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (2)

Ubukhulu Bohlaka

I-KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (3)

Ukuthobela Imithetho

Isici

Ireferensi

Ukusebenza

Ukukhishwa kwe-electrostatic (ESD)

I-IEC/EN 61000-4-2

Iyahambisana nezindinganiso

Ukuphazamiseka Kwama-Electromagnetic (EMI)

I-FCC Ingxenye 15 Isigaba B EN 55022 Isigaba B (CISPR 22A)

Iyahambisana nezindinganiso

Ukuphepha Kwamehlo Nge-Laser

I-FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Umkhiqizo we-laser wekilasi 1

I-ROHS

2002/95/EC

Iyahambisana nezindinganiso

I-EMC

I-EN61000-3

Iyahambisana nezindinganiso

Isithasiselo A. Ukubuyekezwa Kwedokhumenti

Inombolo Yenguqulo

Usuku

Incazelo

1.0

2010-09-01

Ishidi ledatha lokuqala

2.0

2011-09-10

Buyekeza ifomethi kanye nelogo yenkampani

3.0

2012-08-03

Buyekeza izici zamandla -1~4 kuya ku-1~3


  • Okwedlule:
  • Olandelayo:

  • Bhala umlayezo wakho lapha bese uwuthumela kithi